Procedure: To compute $T_r$ of a Tension Member
Connection Details
Bolted connections:
- Minimum pitch (S16 22.3.1)
- Minimum and maximum edge distances (S16 22.3.2 and 22.3.3); (HB page 6-172)
- Minimum end distance (S16 22.3.4)
- Other bolting details (S16 22.3.5.2, 22.3.5.3); (HB pages 6-162 thru 6-182)
Welded connections:
- Minimum size (HB p.6-186)
- Maximum size (HB p.6-186 to 6-187)
Components
- Ensure $L/r$ ratio limit is met (S16 10.4.2.2)
- Determine $F_y$, $F_u$ (HB Tables 6-3, 6-7.)
- Determine relevant dimensions, gross area $A_g$ (HB Part 6 (Properties and Dimensions), direct calculation, S16 12.2)
- Compute $T_r$ for gross area yielding (S16 13.2 a) i))
Components with bolted connections
- Determine bolt hole allowance (S16 12.3.2, 22.3.5)
- Determine net area, $A_n$ (minimum over all potential failure modes) (S16 12.1, 12.3)
- Determine effective net area for shear lag, $A_{ne}$ (S16 12.3.3.1, 12.3.3.2, 12.3.4)
- Compute $T_r$ for net section fracture (S16 13.2 a) iii))
- Compute $T_r$ for block shear (minimum over all potential failure modes) (S16 13.2 a) ii), 13.11)
Components with welded connections
- Determine effective net area for shear lag, $A_{ne}$ (S16 12.3.3.1, 12.3.3.3, 12.3.3.4, 12.3.4)
- Compute $T_r$ for net section fracture (S16 13.2 a) iii))
Components with pin connections, (except eye-bars)
- Ensure detail requirements are met (S16 12.4.2)
- Compute $T_r$ for gross section yield (S16 13.2 b) i))
- Determine effective net areas for tension, $A_{net}$, and shear, $A_{nes}$ (S16 12.4.1)
- Compute $T_r$ for net section fracture (S16 13.2 b) ii) and S16 13.2 b) iii)).
- Use the lesser of the $T_r$ values so computed.
Fasteners
Bolts in bearing-type connections:
- Determine $F_u$ of bolt material (S16 13.12.1.2).
- Determine if threads are intercepted by a shear plane (they often are assumed to be).
- Determine shear resistance $V_r$ (S16 13.12.1.2 c)).
- Determine bearing resistance $B_r$ (S16 13.12.1.2 a) or b)).
Bolts in Slip-critical connections:
- In addition, compare slip resistance, $V_s$ (S16 13.12.2), to service loads.
Fillet welds in shear:
- Determine electrode strength, $X_u$ (S16 Table 4).
- Determine factored resistance, $V_r$ (S16 13.13.2.2).